Transform Your Office Environment with SPON Communications Solutions

Wiki Article

Network PA System for medium to large-scale jobs

Introduction

The XC-9000 system is a completely digital network PA system based on the TCP/IP method. By leveraging the TCP/IP protocol, the system makes certain the right and efficient transmission of all data packets. Not just can it make use of existing computer system networks, such as LANs or the Internet, to transfer program signals, yet also it can also be deployed on a dedicated broadcasting network.

The server is extremely powerful. Also when gotten in touch with a large number of terminals, it can all at once manage the exact same job smoothly. A single-server system can support up to 3000 terminals and enables web server cascading. There are no limitations on the concurrent broadcast networks, accomplishing true full electronic broadcasting .

System Qualities

Versatile PA System Design

The PA system design is simple, including service monitoring software application, network microphones, network amplifiers, network audio speakers, and various other devices.All tools is linked using the TCP/IP intranet protocol, permitting flexible arrangement and very easy management of the system, with free control over program material, network gadgets, and areas through the network.

Ip Paging SystemIp Pa System
Comprehensive Audio Management

The audio management software program consists of built-in attributes for developing program plans, adaptable zoning, and pre-scheduled broadcasts.It supports 24-hour programming, permitting for altering settings during all day

Versatile Sound Resource Support

The system supports various forms of audio sources for sending notifications like online speech and BGM playback. Audio sources can originate from electronic musical applications, CD/DVD gamers, microphones, and so on. Furthermore, the system provides varied functions of sustaining numerous broadcasting functions such as scheduled broadcasting, zoned broadcasting, and emergency situation broadcasting.

Emergency Alarm System Integration

The system has an emergency alarm function and can be incorporated into an emergency alarm system. When the alarm central system obtains the worrying signals, the cable will transmit the signal to devices, which activates the XC-9000, sending out signals to audio speakers

Users might pick to preset settings to trigger full-area or zoned alarm systems in emergency situations. The alarm voices can be found in multiple types and could be modified catering to requirements. For instance, customers can transform language setups, upload and modify their audio resources according to specific demands, such as intruding alarms, smoke alarm or air help alarms, and so on



Emergency Alarm System Integration

The system has an emergency alarm function and can be integrated into a fire alarm system. When the alarm system central unit gets the startling signals, the cable television will certainly send the signal to gadgets, which triggers the XC-9000, sending signals to speakers

Customers can pick to predetermined setups to turn on full-area or zoned alarms in emergency situations. The alarm system voices come in several kinds and could be modified dealing with demands. Individuals can alter language settings, upload and edit their audio resources according to precise requirements, such as intruding alarm systems, fire alarm systems or air help alarms, and so on.

App Control for System Operations

The system makes it possible for mobile app login and use, permitting individuals to launch programs and various other procedures to accredited terminals with the server software program, making sure a structured and convenient experience.

Integrated SIP Compatibility

The system not just allows SIP phones to visit, yet also can be attached to third-party SIP server or IPPBX, which establishes a totally incorporated and compatible communication system with seamless assimilation into existing systems.

Open SDK

When large job like smart park takes place, the system gives an open SDK integrated into third-party application platforms - IP PA System

System Framework

Key Functions

Arranged Playback

The system is able to instantly relay according to the scheduled tasks as long as individuals submit the audio apply for each amount of time of the day to the web server and produce a playback routine.

Area Broadcasting

The system can randomly split a few network tools right into different zones to play defined audio programs or send announcements to any marked area. The quantity of each gadget can be remotely adjusted.

Real-time Broadcasting

The system can relay and capture radio programs or various other outside audio resources in real-time, and at the exact same time transmitted them in sync.

Emergency Alarm Integration

The system can be incorporated with the fire alarm system for control. When a smoke alarm signal is triggered, it immediately turns on the emergency program function and sustains nearby floor alarms. It also enables for hand-operated emergency broadcasting by clicking a solitary button.

SIP Phone Integration

The system can be integrated with SIP web servers, enabling online speech of voice broadcasting via SIP phones to send statements anytime and anywhere.

CCTV Integration

The electronic tools such as IP POE Audio speakers embraces the global standard ONVIF method, which enables their voices to be transmitted via VMS platforms. The terminals can likewise be integrated with CCTV systems for synchronized program.

Key Products

Sound Monitoring Software Program XC-9000

B/S style, sustains cross-platform applications. Covers traditional broadcasting system functions, permitting for dividers administration. Unified monitoring of terminals within the system, viewing job condition, and set volume modification, and so on. Sustains building multi-level web server architectures, deploying monitoring according to customer geographical regions. Supplies SDK development packages for second development and assimilation with other system platforms.

Network Paging Console XC-9038N

Power: DC12V/1.5 A. Display: 4-inch touchscreen, resolution 480 * 480. Interaction Protocols: TCP/IP, UDP, SIP. Signal-to-Noise Ratio: > 80dB. Frequency Reaction: 100Hz~ 16KHz. Running Temperature level: 0~ 45 ℃. Measurements: 144 * 144 * 34.1 mm.

Network Paging Console XC-9037N

Power Supply: DC12V/1.5 A. Present: 4-inch touchscreen, resolution 480 * 480. Interaction Procedures: TCP/IP, UDP, SIP. Signal-to-Noise Ratio: > 80dB. Regularity Reaction: 100Hz~ 16KHz. Running Temperature: 0~ 45 ℃. Measurements: 144 * 144 * 34.1 mm.

Network Horn Audio Speaker GEN-6391A03

Power Supply: DC24V/2.7 A or POE. Communication Method: TCP/IP, UDP, SIP, ONVIF. Signal-to-Noise Ratio: > 80dB. Regularity Feedback: 100Hz~ 18KHz. Intercom: Sustained, Integrated Microphone. Running Temperature: -20~ 50 ℃. Measurements: 283.1 * 224.3 * 269mm.

Network Ceiling Audio Speaker GEN-6211A03

Power Supply: DC 24V/1A or POE. Interaction Procedures: TCP/IP, UDP, SIP, ONVIF. Signal-to-Noise Ratio: > 80dB. Regularity Action: 100Hz~ 18KHz. Running Temperature: -20 to 50 ° C. Dimensions: φ213 x 165mm.

Network Wall Mount Audio Speaker GEN-6011A03

Power Supply: DC24V/1A or POE. Interaction Method: TCP/IP, UDP, SIP, ONVIF. Signal-to-Noise Ratio: > 80dB. Regularity Response: 100Hz~ 18KHz. Operating Temperature: -20~ 50 ℃. Measurements: 193x151.5 x292mm.

Network Column Audio Speaker GEN-6191A03


Power Supply: DC24V/1A or POE. Interaction Method: TCP/IP, UDP, SIP. Signal-to-Noise Ratio: > 90dB. Regularity Response: 45Hz~ 18KHz. Running Temperature level: -10~ 55 ℃. Measurements: 296x140x130mm.

Network Audio Bridge GEN-3101A01

Power Supply: POE. Communication Protocol: TCP/IP, UDP, SIP. Signal-to-Noise Proportion: > 85dB. Frequency Feedback: 50Hz~ 20KHz. Running Temperature: -10~ 55 ℃. Dimensions: 126x66x27mm.

Network Digital Amplifier XC-9508P

Power Supply: AC100V~ 240V, 50/60Hz. Power: 130W, 260W, 360W, 500W. Communication Protocol: TCP/IP, UDP, SIP. Signal-to-Noise Ratio: > 80dB. Regularity Feedback: 60Hz~ 18KHz. Operating Temperature level: -10~ 50 ℃. Measurements: 440x300x44mm.

Zone Combining Digital Amplifier NBS-2301

Power Supply : A/C 220V, 50Hz. Power : 130W , 260W , 360W , 550W , 700W. Interaction Procedure : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP. Signal-to-Noise Proportion :. Mic Input 01: ≥ 65dB,. Mic Input 02/03: ≥ 80dB,. Aux Input 01/02: ≥ 82dB. Frequency news Response :. Mic Input 01: 80Hz~ 14kHz. Mic Input 02/03: 60Hz~ 16kHz. Aux Input 01/02: 60Hz~ 16kHz. Operating Temperature :. 10 ℃~ +50 ℃ (14 ℉~ 122 ℉) Measurements : 483x430x88mm.

IP Interface System NAC-5003

Power Supply: AC100V~ 240V, 50/60Hz. Communication Method: TCP/IP, UDP. User interfaces: 1 Ethernet port, 32 alarm inputs, 8 alarm system outcomes. Operating Temperature: -10~ 50 ℃. Dimensions: 483x259x44mm.

Solution For Institution



Versatile Zoning Program:

The totally network terminals can recognize adaptable zoning options, permitting broadcasting alerts to various zones or individual terminals ( devices).

School Bell System:

It provides institution bell system at the beginning/ending of the class - SPON Communications. Numerous situations can be developed, including various scheduled program tasks according to summer/winter timetable

Fire Alarm System Integration

It supports combination with smoke alarm systems, allowing emergency alarm signals to be integrated right into the PA system.

Class Sound Amplification

Terminals support daily applications in classroom scenes. They can be linked to projectors or interactive whiteboard for audio amplification.

Spon CommunicationsIp Paging System

Smart Road Lamp/Security Pole

Support SIP Procedure:

Integrated SIP method for smooth combination with network interaction systems.

VMS Operatings Systems Integration:

Integrated ONVIF procedure for combination with VMS platforms.

Third-Party Integration:

Integrated In HTTP API for integration with 3rd event systems.

Voice Alarm System Triggering:

Constructed in alarm system input user interface for activating voice alarms with cameras.

Option For Hotel

Area Control by Flooring:

The system supplies full network setups, dividing areas relying on various floors and control over each zone separately.

Smoke Alarm Assimilation:

The system can be incorporated with fire alarm system, making it possible for combination of emergency alarm signals into the broadcasting system.

Scheduled Broadcasting:

It supports programmable scheduled broadcasting, allowing versatile arrangements according to various requirements.

Emergency situation Broadcasting:

It supports emergency broadcasting for webpage the whole location, making it possible for one-click emergency communication.

Solution For Manufacturing facility

Area Broadcasting:

It allows broadcasting to any kind of area, ensuring no disturbance in between various areas.

Alarm Triggering:

Terminals have various sort of interfaces, allowing to activate alarm systems when linked with cameras.

All Network Tools:

Implementation of completely network tools substantially reduces the difficulty of running such as checking devices on unsafe sites, and therefore safeguarding people and property.

The release of all network devices significantly decreases the problem of operation and maintenance administration

Integrated SIP Phones:

The system can be incorporated with SIP phone and program notices making use of SIP phones at any moment and anywhere. Two-way audio talkback between Check Out Your URL SIP phones and IP POE Audio speakers makes it very easy for checking tools being in office or other workplaces.

The XC-9000 system is a completely electronic network PA system based on the TCP/IP method. By leveraging the TCP/IP protocol, the system guarantees the efficient and correct transmission of all data packages. The system sustains different kinds of audio resources for sending alerts like real-time speech and BGM playback. In enhancement, the system offers diverse features of supporting different broadcasting functions such as set up broadcasting, zoned broadcasting, and emergency broadcasting.

The system can be integrated with the fire alarm system for control.

Report this wiki page